TENS-2000 (with safety cover)
3 Mode without Timer

Channels: Dual, Isolated between channels
Modes: Burst, Constant, Modulation
Pulse Width: 60 to 250 microseconds, 
adjustable
Pulse Amplitude (intensity): 0 to 80 mA each
channel, adjustable (500 ohm load)
Pulse Frequency: 2 to 150 Hz adjustable
Modulation Mode: Pulse width automatically
varies is a cyclical pattern over an
interval of nominally 4 seconds
Burst Mode: 7 pulses per burst, 2 
bursts per second, 100Hz 
internal frequency of burst
Battery Life: 70 hour average (alkaline)
Waveform: Modified square wave 
with zero net direct current
* All values have +/- 10% tolerance

 $52.95

 

TENS-2500 (with safety cover)
3 Mode with Timer

Channels: Dual, Isolated between channels
Modes: Burst, Constant, Modulation
Pulse Width: 60 to 250 microseconds, 
adjustable
Pulse Amplitude (intensity): 0 to 80 mA each
channel, adjustable (500 ohm load)
Pulse Frequency: 2 to 150 Hz adjustable
Timer: 30 Min, 60 Min, or Constant
Modulation Mode: Pulse width automatically
varies is a cyclical pattern over an
interval of nominally 4 seconds
Burst Mode: 7 pulses per burst, 2 
bursts per second, 100Hz 
internal frequency of burst
Battery Life: 70 hour average (alkaline)
Waveform: Modified square wave 
with zero net direct current
* All values have +/- 10% tolerance

 $56.50

 

TENS 6000 (with safety cover)
Digital TENS with Timer

Channels: Dual
Modes: Burst, Normal, MRW, SD, Bi-Pulse
Pulse Width: 50-300 microseconds,
adjustable
Pulse Amplitude: 0 to 80 mA each channel
Pulse Frequency: Variable, 2-150 Hz
Waveform: Asymmetric biphasic square
pulse
Timer: 5 to 90 Min, or constant time
Compliance Timer: 60 sets of operation
records, 999 hours record time
* All values have +/- 10% tolerance

 $72.85

 

EMS-3000 (with safety cover)
Muscle Stimulator

Channels: Dual, Isolated between channels
Modes: Burst, Constant, Modulation
Pulse Amplitude: 0 to 100 mA Peak
at 500 s/channel
Pulse Frequency: Adjustable,
2-120 Hz
Cycle On/Off: 1-30 sec.
On Ramp: Adjustable 1-8 sec.
Battery Life: Approx. 70 hours
Waveform: Modified square wave with 
zero net direct current
* All values have +/- 10% tolerance

$57.25

 

EMS 6500 (with safety cover)
Digital EMS with Timer

Channels: Dual
Modes: Synchronous (S), Constant (C), and
Alternate (A)
Pulse Amplitude: 0 to 80 mA peak into 
500 ohm load each channel, adjustable
Pulse Frequency: 2 to 120 Hz
Pulse Ramp: 1 to 8 seconds
Contraction: Variable Control (2-99 Sec)
Relaxation: Variable Control (2-99 Sec)
Waveform: Asymmetric biphasic square
pulse wave with zero net direct current
Compliance Timer: 60 sets of operation
records, 999 hours record time
* All values have +/- 10% tolerance

$72.85

 

IF-4250
Interferential Stimulator

Channel: Dual
Pulse Width: 125 microseconds for each phase
Pulse Amplitude: Adjustable 0-50 mA peak
at 500 S/channel
Carrier Frequency: 4000 Hz fixed
Difference Frequency: (1 +/- 0.5) ~
(250+/-10%) Hz adjustable
Interference Frequency: Channel B
Auto Sweep: 4-45 bps, 80-150 bps,
4-set
Constant Mode: 4-400 bps, adjustable 
Waveform: Symmetrical Biphasic Square
Four Frequency Shift: Continuous, 1/1 
abrupt, 8/8 abrupt, 
10/10 ramped

 $205.00

 

PGS-123
Pulsed-Galvanic Stimulator

Channel: Single
Output Mode: Synchronous or Alternation.
Alternation mode-LED alternates between green and red color
Pulse Rate: 2-100 Hz
Wave Form: Positive or negative wave form
Pulse Duration: 5 ms
IntraPulse Interval: 100 ms.
All values have +/- 20% tolerance

$205.00

 

Micro-850
Microcurrent Stimulator (with safety cover)

Channels: Dual
Output Waveform: Modified square DC biphasic pulses of 0.3Hz, 8Hz, and 80Hz changing polarity at intervals of 1 seconds.
Timer: 20, 40 minutes and constant
Frequency: 0.3, 8 and 80Hz
Output Voltage: 12 Volts
All values have a +/- 10% tolerance

$65.75

 

IF-2206
Digital Interferential w/True Sine Wave

Channels: Dual, Isolated between channels
Pulse Amplitude: Adjustable, 0-60mA into
500 ohm each channel
Carrier Frequency: 4000 Hz fixed
Waveform: Symmetrical Balanced Sine Wave
Sweep Time: 15 sec.
Frequency Function Mode: Constant, Auto Sweep, Frequency Shift
Output Configuration: Quadra polar (4 electrodes)
Patient Lock System: Yes
Pulse Duration: 125 bps max.
Timer: 15, 30
* All values have +/- 10% tolerance

$205.00
 

 